Hydraulic breaker diaphragms (also referred to as accumulator membranes) are critical wear components in Furukawa rock hammers. Installed inside the hydraulic accumulator, the diaphragm separates nitrogen gas ($N_2$) from high-pressure hydraulic oil. Its primary function is to store energy during the piston return stroke and release it instantly to maximize impact power while dampening hydraulic shock waves to protect the excavator pump.
When a diaphragm tears or degrades, nitrogen gas escapes, causing reduced blow energy, erratic hammering, and intense hydraulic hose vibration. Replacing worn membranes with high-grade, oil-resistant rubber diaphragms restores peak performance and guards against costly accumulator cylinder damage.
Below is a complete size specification chart and cross-reference guide for Furukawa F-Series and HB-Series Hydraulic Breaker Diaphragms.
Furukawa Diaphragm Size & Specification Reference Chart
| Item No. | Brand | Model / Part Name | Outer Diameter & Specification Size (mm) |
| 1 | FURUKAWA | F-1 Diaphragm | 82 × 19 |
| 2 | FURUKAWA | F-2 Diaphragm | 100 × 17 |
| 3 | FURUKAWA | F-3 Diaphragm | 109 × 16 |
| 4 | FURUKAWA | F-4 Diaphragm | 120 × 24 |
| 5 | FURUKAWA | F-5 Diaphragm | 130 × 22 |
| 6 | FURUKAWA | F-6 Diaphragm | 109 × 16 |
| 7 | FURUKAWA | F-9 Diaphragm | 130 × 22 |
| 8 | FURUKAWA | F-12 Diaphragm | 140 × 40 |
| 9 | FURUKAWA | F-15 Diaphragm | 149.3 × 43.2 |
| 10 | FURUKAWA | F-19 Diaphragm | 149.3 × 43.2 |
| 11 | FURUKAWA | F-22 Diaphragm | 169 × 36.6 |
| 12 | FURUKAWA | F-27 Diaphragm | 169 × 36.6 |
| 13 | FURUKAWA | F-35 Diaphragm | 190 × 40.3 |
| 14 | FURUKAWA | F-45 Diaphragm | 209 × 52 |
| 15 | FURUKAWA | F-70 Diaphragm | 237 × 41 |
| 16 | FURUKAWA | F-300 Diaphragm | 109 × 16 |
| 17 | FURUKAWA | HB-1G Diaphragm | 65 × 10 |
| 18 | FURUKAWA | HB-2G Diaphragm | 82 × 19 |
| 19 | FURUKAWA | HB-3G Diaphragm | 100 × 17 |
| 20 | FURUKAWA | HB-5G Diaphragm | 100 × 17 |
| 21 | FURUKAWA | HB-8G Diaphragm | 120 × 24 |
| 22 | FURUKAWA | HB-10G Diaphragm | 140 × 40 |
| 23 | FURUKAWA | HB-15G Diaphragm | 149.3 × 43.2 |
| 24 | FURUKAWA | HB-18G Diaphragm | 149.3 × 43.2 |
| 25 | FURUKAWA | HB-20G Diaphragm | 169 × 36.6 |
| 26 | FURUKAWA | HB-30G Diaphragm | 190 × 40.3 |
| 27 | FURUKAWA | HB-40G Diaphragm | 209 × 52 |
| 28 | FURUKAWA | HB-50G Diaphragm | 237 × 41 |
| 29 | FURUKAWA | HB-200 Diaphragm | 135 × 26 |
| 30 | FURUKAWA | HB-400 Diaphragm | 165 × 20 |
| 31 | FURUKAWA | HB-700 Diaphragm | 165 × 20 |
Material & Performance Requirements
Because hydraulic breaker accumulators undergo continuous rapid flexing under high pressures, premium replacement membranes feature:
- High-Flex Hydrogenated Nitrile Rubber (HNBR) / NBR Rubber: Formulated for superior tear strength, fatigue resistance, and gas impermeability to prevent nitrogen migration.
- Extreme Heat & Fluid Compatibility: Resistant to high hydraulic oil temperatures (up to 120°C / 248°F) and harsh anti-wear hydraulic oil additives.
- Precise Molding Tolerances: Engineered to match OEM shell dimensions exactly, preventing pinch damage or seal degradation during installation.
Signs Your Breaker Diaphragm Needs Replacement
- Loss of Impact Power: The breaker loses strike force or operates sluggishly despite full hydraulic flow from the base machine.
- Excessive Hose Violent Vibration: Severe shaking in the supply and return hydraulic lines indicates the accumulator is no longer absorbing hydraulic pulsation.
- Nitrogen Gas Loss: The accumulator repeatedly loses $N_2$ charge pressure over short operating intervals.
- Oil in Gas Chamber: Hydraulic oil drips from the nitrogen charging valve during pressure checks.
Best Practices for Replacement
- Depressurize Completely: Always release all nitrogen gas pressure from the accumulator gas valve before disassembling the accumulator shell.
- Clean the Chamber Shell: Inspect the interior accumulator cavity for rust, metal shavings, or scale before placing the new diaphragm in position.
- Use Correct $N_2$ Gas Charge: Re-fill the accumulator exclusively with pure Nitrogen gas ($N_2$) to the factory-specified pressure rating. Never use oxygen, shop air, or flammable gases.